
Bromate has suddenly become the most searched word in the packaged drinking water (PDW) industry. On 22-23 November 2026 FSSAI announced prosecution sanction and then clarified that its prohibition of sale covered one batch from a Goa plant, where the primary lab reported bromate at 0.012 mg/l against the 0.01 mg/l limit. Whatever the outcome of that case, every plant that uses ozone should now ask one question: can we prove our water stays under the bromate limit, batch after batch?
This guide explains the rule, why bromate forms, the procedure to control it, and the opportunity for plants that get it right.
Policy: what the bromate rule says
Under the FSSAI standard for packaged drinking water, bromate (as BrO3) has a maximum limit of 0.01 mg/l (10 micrograms per litre). Water above this limit can be treated as non-compliant, and FSSAI has shown it will act under the Food Safety and Standards Act, 2006 when a sample fails.
The Indian limit is the same as the international benchmark. Health Canada's bromate guideline notes that the WHO guideline, the US EPA limit and the EU parametric value are all 0.01 mg/l.
| Rule or benchmark | Requirement | Source |
|---|---|---|
| FSSAI PDW standard - bromate | Max 0.01 mg/l | FSSAI |
| WHO, US EPA, EU, Health Canada | 0.01 mg/l | Health Canada guideline document |
| FSSAI Scheme of Testing (from 1 Jan 2026) | Monthly microbiological testing, source-water testing at FSSAI-notified NABL labs, records kept 5 years | FSSAI order of 17 Dec 2025 |
| High-risk food category (PDW, mineral water) | Pre-licence inspection, risk-based annual inspection, annual third-party audit for central licensees | FSSAI order of 29 Nov 2024 |
| Appeal against a failed sample | Referral lab report is final | FSSAI, as reported 24 Nov 2026 |
Why bromate forms in a water plant
Bromate is not usually present in raw water. It is created during treatment. Health Canada's technical document identifies two main sources:
- Ozonation - ozone reacts with bromide that occurs naturally in the source water.
- Hypochlorite solutions - bromate can be present in sodium hypochlorite as a by-product of its manufacture.
The same document says bromate is difficult to remove once formed, so the recommended approach is to control the ozonation process itself. Factors that generally push bromate up include a higher ozone dose and more bromide in the source water; a lower pH generally reduces formation.
Indian standards require PDW to be disinfected but do not prescribe ozone. Many plants use ozone because it leaves no taste, which is exactly why ozone control deserves a written procedure.
Procedure: a bromate control routine for your plant
- Know your source water. Ask your NABL lab to test source water for bromide along with the parameters you already test under the Scheme of Testing. Re-test when you change or add a borewell.
- Fix the ozone settings in writing. Record the generator setting, ozone dose, contact time and residual for each batch. Use the lowest dose that still achieves disinfection and microbiological compliance.
- Test the finished product for bromate at an FSSAI-notified NABL lab at a fixed frequency, and again after any change in source, equipment or ozone setting.
- Control chemicals. If you use hypochlorite for cleaning or disinfection, buy from a known supplier, keep stock fresh and record batch numbers.
- Batch coding and traceability. FSSAI's recent action was tied to a single batch number. Clear batch codes and dispatch records let you isolate one batch instead of the whole plant.
- Keep a root cause analysis (RCA) format ready. FSSAI directed the company in the Goa case to conduct an RCA. Have a template covering source water, ozone logs, chemicals, maintenance and corrective action.
- Know the appeal route. If a sample fails, the FSS Act allows an appeal to a referral lab. See our guide on sampling and appeal rights.
What this means for water plant owners
PDW is a high-risk category, monthly testing is compulsory, and FSSAI has now publicly acted on a bromate result. A food safety officer can lift samples from your plant or from the market at any time. If your ozone logs, test reports and batch records are in order, a sample is routine. If they are not, a single failed batch can lead to prohibition of sale, an improvement notice or prosecution.
Check that your FSSAI licence category and scope are correct, and that your CGWA NOC and pollution board consent cover each borewell and discharge point you actually use.
The opportunity for compliant plants
After a widely reported case, brand owners, institutional buyers and distributors have a clear reason to ask suppliers and contract packers for recent bromate and microbiological reports. A plant that can share a clean, dated testing file within a day stands out. Documented control also makes the annual third-party audit and FSSAI inspections smoother. BIS certification remains voluntary nationally (except where a state requires it, as Uttar Pradesh now does), but the same records support a BIS application if you choose one.
How ClearPath Compliance India can help
We review your FSSAI licence, Scheme of Testing records, ozone and batch logs, and help you set up a bromate control SOP and RCA format before an inspection. For new projects we handle the full packaged drinking water plant licence set: FSSAI, CGWA NOC, CTE/CTO, factory licence and fire NOC. Call or WhatsApp +91 92521 92607.
Sources
- Business Standard (PTI), 24 Nov 2026 - FSSAI clarification and company statement
- Daily Jagran (ANI), 24 Nov 2026 - batch, lab results and RCA direction
- Health Canada - Guideline Technical Document: Bromate
- FSSAI - Packaged drinking water standard notice (bromate 0.01 mg/l)
General information only, not legal or technical advice. Rules and limits are as reported or published on the dates stated. Brand and company names are trademarks of their owners, used for identification only. This article is not sponsored or endorsed by any brand named.